Sloan G2 Flushometer Battery Replacement

When Required, Replace Batteries With Four (4) Alkaline AA-Size Batteries.

 

  1. Loosen the two (2) Screws on top of unit.
  2. Remove the complete Cover Assembly.
  3. Lift the Sensor Module from its Plate. Unplug the Electrical Connector from Battery Compartment Cover.
  4. Loosen the Retaining Screw on Battery Compartment Cover and remove Battery Compartment Cover.
  5. Install four (4) Alkaline AA-Size Batteries.
  6. Install Battery Compartment Cover and secure with Retaining Screw. Make certain that Battery Compartment Cover is fully compressed against Gasket to provide a seal; Do Not overtighten.
  7. Plug the Electrical Connector into the Battery Compartment Cover.
  8. Reinstall the Sensor Module onto the Plate.
  9. Reinstall the complete Cover Assembly onto the Plate.
  10. Tighten the two (2) Screws on top of the unit.
Note: Water does not have to be turned off to replace Batteries.